ISSI
IS61LV256
Integrated Silicon Solution, Inc.
Rev. F 0296
SR81995LV61
2-3
DC ELECTRICAL CHARACTERISTICS
(Over Operating Range)
Symbol Parameter
Test Conditions
Min.
Max.
Unit
V
OH
Output HIGH Voltage
V
CC
= Min., I
OH
= –2.0 mA
2.4
—
V
V
OL
Output LOW Voltage
V
CC
= Min., I
OL
= 4.0 mA
—
0.4
V
V
IH
Input HIGH Voltage
2.2
V
CC
+ 0.3
V
V
IL
Input LOW Voltage
(1)
–0.3
0.8
V
μ
A
I
LI
Input Leakage
GND
≤
V
IN
≤
V
CC
Com.
Ind.
–2
–5
2
5
I
LO
Output Leakage
GND
≤
V
OUT
≤
V
CC
, Outputs Disabled
Com.
Ind.
–2
–5
2
5
μ
A
Notes:
1. V
IL
= –3.0V for pulse width less than 10 ns.
2. Not more than one output should be shorted at one time. Duration of the short circuit should not exceed 30 seconds.
CAPACITANCE
(1,2)
Symbol
Parameter
Conditions
Max.
Unit
C
IN
Input Capacitance
V
IN
= 0V
6
pF
C
OUT
Output Capacitance
V
OUT
= 0V
5
pF
Notes:
1. Tested initially and after any design or process changes that may affect these parameters.
2. Test conditions: T
A
= 25
°
C, f = 1 MHz, Vcc = 3.3V.
POWER SUPPLY CHARACTERISTICS
(1)
(Over Operating Range)
-12 ns
Min. Max.
-15 ns
Min. Max.
-20 ns
Min. Max.
-25 ns
Min. Max.
Symbol Parameter
Test Conditions
Unit
I
CC
1
Vcc Operating
Supply Current
V
CC
= Max.,
CE
= V
IL
I
OUT
= 0 mA, f = 0
Com.
Ind.
—
—
50
—
—
—
50
60
—
—
50
60
—
—
50
60
mA
I
CC
2
Vcc Dynamic Operating
Supply Current
V
CC
= Max.,
CE
= V
IL
I
OUT
= 0 mA, f = f
MAX
Com.
Ind.
—
—
100
—
—
—
90
100
—
—
80
90
—
—
70
80
mA
I
SB
1
TTL Standby Current
(TTL Inputs)
V
CC
= Max.,
V
IN
= V
IH
or V
IL
CE
≥
V
IH
, f = 0
V
CC
= Max.,
CE
≤
V
CC
– 0.2V,
V
IN
> V
CC
– 0.2V, or
V
IN
≤
0.2V, f = 0
Com.
Ind.
—
—
10
—
—
—
10
20
—
—
10
20
—
—
10
20
mA
I
SB
2
CMOS Standby
Current (CMOS Inputs)
Com.
Ind.
—
—
2
—
—
—
2
5
—
—
2
5
—
—
2
5
mA
Notes:
1. At f = f
MAX
, address and data inputs are cycling at the maximum frequency, f = 0 means no input lines change.
OPERATING RANGE
Range
Commercial
Industrial
Ambient Temperature
0
°
C to +70
°
C
–40
°
C to +85
°
C
V
CC
3.3V +10%, –5%
3.3V
±
5%